Potential of the in vitro dissolution method DissolvIt® to predict pharmacokinetic outcomes

Type: Poster

Maria Malmlöf1, Iwona Klups1, Ewa Selg1, Per Bäckman2, Bo Olsson2, Elizabeth Bielski3, Bryan Newman3, Ross Walenga4, Steven Chopski4 & Per Gerde1

1Inhalation Sciences, Hälsovägen 7, Huddinge, 141 57, Sweden

2Emmace, Scheelevägen 22, Lund, 223 63, Sweden

3Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Building 75, 10903 New Hampshire Ave, Silver Spring, MD 20993, USA

4Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Building 75, 10903 New Hampshire Ave, Silver Spring, MD 20993, USA

Summary

A general goal within inhalation research is to establish an in vitro dissolution method that can predict pharmacokinetic (PK) outcomes of inhaled active pharmaceutical ingredients (APIs). DissolvIt was previously developed with the aim to physiologically resemble the airways in design and generate more clinically representative data, such as concentration-time graphs that describe maximum plasma concentration (Cmax) and time to maximum concentration (Tmax) of the inhaled API obtained from PK measurements. In addition, DissolvIt can provide cumulative dissolution graphs similar to other conventional in vitro dissolution methods. Here, DissolvIt dissolution data of fluticasone propionate (FP) and salmeterol (Sal) in Seretide Evohaler 250/25 pressurized metered dose inhaler (pMDI) was directly compared with lung-specific PK data from the isolated perfused and ventilated (IPL) rat lung. The concentration curves over time, the magnitude of Cmax for both APIs and the cumulative absorption of Sal and FP were very similar in both systems. Furthermore, the DissolvIt FP data were used for physiologically based biopharmaceutical modelling (PBBM). The PBBM showed good agreement of predicted FP plasma-time profiles generated from the DissolvIt data to the observed clinical FP plasma concentration-time profiles. This, taken together, shows the potential of DissolvIt as an in vitro dissolution method for development of both new and generic inhalation drug products.