Summary
This study pursues the approach of tailor-made carrier particles for inhalation. The design is guided by in-silico tests to evaluate potential carrier particles with the best performance. In a set of three different numerical simulation models, based on the discrete element method, the particle-particle interactions between the tested carrier geometry and a model drug were analysed. First, the mixing of an interactive mixture was mimicked for a single carrier particle with randomly surrounding drug particles that attach on the surface of the carrier upon contact. The resulting loaded carrier was tested in a particle-particle collision with another carrier as well as in a particle-wall collision and the detachment of the drug particles was assessed as the detachment rate. In the second part of this study, selected carrier particles were 3D-printed using two-photon-polymerisation on a novel multi-focus platform enabling production of a sufficient number of particles to form a powder bulk which was then blended with the model drug budesonide. The various mixtures were tested for homogeneity and aerodynamic performance with the Fast Screening Impactor. As an indicator for the performance the fine particle fraction below 5 µm (FPF) was determined. The results of the in-silico approach and the experimental tests were compared and showed consistency in the trends. The detachment rate of the two different collision setups were compared to the FPF. Significantly better results were found for the carrier geometry called Pharmacone. Therefore, it can be concluded that the carrier geometry has an influence on the inhalation performance.